Measuring the activation time of a solenoid

by FMashiro   Last Updated September 11, 2019 10:25 AM

I'm trying to measure the activation time of a pull-type solenoid.

When the solenoid doesn't have a load connected to it, you can measure it's activation time through the current it consumes. At first, the solenoid will consume current until the magnetic field is strong enough to move the armature, at which point the current consumption decreases until the armature has reached it's holding position. At that point the current will rise a bit more until it stabilizes.

However, if there is a load attached to the armature, the curve of current consumption never dips, which means that you can't quite tell at what point the armature is fully pulled in.

I'm wondering what technique could be used or is standard for measuring the time it takes the armature to reach the end position with a load.

I've thought of making the load close a circuit so you could measure the time between activation of the solenoid and the closing of the measuring circuit but I'm wondering if there are other approaches which I haven't thought of.

(p.s. if this is off-topic let me know and I'll remove the question)



Answers 1


If you don't need very high accuracy/precision, then the voltage across the solenoid can start a timer and a limit switch can stop it. For more accuracy, a small vane entering an optical interrupter can be the stop signal.

AnalogKid
AnalogKid
September 11, 2019 09:55 AM